Variable Frequency Drives (VFD) - Optidrive E3

Quick Enquiry
Optidrive Coolvert Specification

We are Dealer, Wholesaler, Supplier, Exporter, Trader of Invertek Drives VFD Drives (Variable Frequency Drives), Optidrive Coolvert from Pune, Maharashtra, India.

kW HP Amps Size Model Code Product Family Frame Size Voltage Code Power Rating Code Input Phases EMC Filter Heatsink/Coldplate Power Technology
200–240V ± 10%
1 Phase Input
1.5 2 7.0 2 CV - 2 2 0070 - 1 F # P
3 4 12 2 CV - 2 2 0120 - 1 F # P
4 5.5 16.0 2 CV - 2 2 0160 - 1 F # P
5.5 7.5 20.0 2 CV - 2 2 0200 - 1 F # P
380–480V ± 10%
3 Phase Input
5.5 7.5 14 2 CV - 2 4 0140 - 3 F # E
7.5 10 18 2 CV - 2 4 0180 - 3 F # E
11 15 24 2 CV - 2 4 0240 - 3 F # E
15 20 30 3 CV - 3 4 0300 - 3 F # E
18.5 25 39 3 CV - 3 4 0390 - 3 F # E
22 30 46 4 CV - 4 4 0460 - 3 F # E
30 40 58 4 CV - 4 4 0580 - 3 F # E
37 45 65 5 CV - 5 4 0650 - 3 F # E
40 50 75 5 CV - 5 4 0750 - 3 F # E

Replace # in model code with colour-coded option

Heatsink/Coldplate

  • HHeatsink version
  • CColdplate version

Dimensions

Heatsink Version (dimensions in mm)

Heatsink Dimensions
Size A B C D E
mmin mmin mmin mmin mmin
22268.91656.51777.0722.81044.1
327810.91947.62007.9843.31164.6
436414.32409.42319.1983.91335.2
536414.32409.42409.41074.21335.2

Note: The Heatsink version can be mounted on the backplate of a panel using the optional panel mounting kit (sold separately).

Coldplate Version (dimensions in mm)

Coldplate Dimensions
Size A B C
mmin mmin mmin
22268.91656.51144.5
327810.91947.61265.0
436414.32409.41405.5
536414.32409.41415.5

Technical Specifications

Input Ratings
Supply Voltage 200 – 240V ± 10%
380 – 480V ± 10%
Supply Frequency 48 – 62Hz
Displacement Power Factor > 0.98
Phase Imbalance 3% Maximum allowed
Inrush Current < rated current
Output Ratings
Output Power 200V: 7.0A to 20A
400V: 14A to 75A
Overload Capacity 130% rated current for 10s
Output Frequency 0 – 500Hz
Acceleration Time 0.01 – 600 seconds
Deceleration Time 0.01 – 600 seconds
Typical Efficiency > 98%
Ambient Conditions
Temperature Storage: −40 to 70°C
Operating: −20 to 60°C
Altitude Up to 1000m ASL without derating
Up to 2000m maximum
Humidity 95% Max, non condensing
Vibration Conforms to EN61800-5-1
Enclosure
Ingress Protection (IP) Front IP20
Rear (Through Panel Mounting) IP55
Coated PCBs Designed for operation in 3S2/3C2 environments according to IEC 60721-3-3
Programming
Modbus RTU (RS485) Modbus RTU on Pluggable terminals and through RJ45 port
PC Tools PC Tools software for Diagnostics and parameter configuration (RJ45 port only)
Keypad Optional Remote Keypad with TFT display for diagnostic and programming
Smartphone app Optitools Mobile
Control Specification
PWM Frequency 4 – 32kHz
Control Modes Modbus RTU (RS485)
Terminal Control Digital / Analogue
Terminal Control PI mode
Master / Slave Mode
Safe Torque Off (STO)
IEC 61800-5-2:2016 SIL 3
UL 61800-5-2 : 2022 SIL 3
Independent Approval TUV Rheinland / UL
Maintenance & Diagnostics
Fault Memory Last 3 trips stored with time stamp
Data Logging Logging of data prior to trip for diagnostic purposes
Monitoring Hours Run Meter
kWH
Conformance
The Coolvert product range conforms to the relevant safety provisions of the following council directives: 2014/30/EU (EMC), 2014/35/EU (LVD), 2006/42/EC (Machinery Directive), 2011/65/EU (RoHS 2) and 2009/125/EC (Eco-design)
Design and manufacture is in accordance with the following harmonised European standards:
BSEN 61800-5-1: 2007 & A1: 2017 Adjustable speed electrical power drive systems. Safety requirements. Electrical, thermal and energy.
BSEN 61800-3:2018 Adjustable speed electrical power drive systems. Part 3: EMC requirements and specific test methods (IEC 61800-3:2017).
BSEN 61800-9-2:2017 Ecodesign for power drive systems – Energy efficiency indicators
BSEN 60529: 1992 & A2: 2013 Specifications for degrees of protection provided by enclosures
UL 61800-5-1 cUL Listed
cUR Recognised for the coldplate variants
BSEN 61000-3-12: 2011 EMC Limits for harmonic currents (equipment >16 A and ≤75 A per phase)
BSEN 61000-3-2:2019 EMC Limits for harmonic current emissions (single phase input variants only)